NEC 2023 Code Changes Update part 1

Approved by the New Mexico Construction Industries Division for New Mexico Electricians License Renewal.

Yes! We Are Approved by the New Mexico Construction Industries Division for New Mexico Electricians' License Renewal.

Electrical Online Course Name Credit Hours Credit Type Course Number Course Availability Course Price
NEC 2023 Code Changes Update part 18.0 Code Change 2023-105 9/20/2023
-through-
9/20/2026
$69
-10

$59
This New Mexico Electrical Continuing Education License Renewal Course reviews the most important updated 2023 NEC Changes in detail. This course will earn you 8 hours of Code Change electrical continuing education for your electrical license renewal with the New Mexico Construction Industries Division. The NM CID has approved this course for 2023 license renewal. This course is Part 1 and reviews the top 75 sections of the most important National Electrical Code Changes in 2023; From Article 90 to Article 314. This course is best when followed by taking Part 2.
New? First Time? Register for courses for free.

Returning For More? Sign In To Your Account
NEC 2023 Code Changes Update part 1 Course Topics:
  90.5(C) Explanatory Material.
  Article 100.
  Article 100 Definitions. Accessible (as applied to wiring methods).
  Article 100 Definitions. Counter (Countertop).
  Article 100 Definitions. Likely to Become Energized.
  Article 100 Definitions. Permanently Installed Swimming Pools and Storable Pools.
  Article 100 Definitions. PV String Circuit.
  Article 100 Definitions. Servicing.
  Article 100 Definitions. Short Circuit.
  Article 100 Definitions. Stranding.
  Article 100 Definitions. Work Surface.
  110.3(A)(8) Cybersecurity.
  110.3(B) Installation and Use.
  110.16(B) Service Equipment and Feeder Supplied Equipment.
  110.17 Servicing and Maintenance of Equipment.
  110.20 Reconditioned Equipment.
  110.22(A) Identification of Disconnecting Means.
  110.26(A)(4) Limited Access.
  110.26(A)(6) Grade, Floor, or Working Platform.
  110.26(C)(2) Large Equipment.
  110.26(C)(3) Personnel Doors.
  110.26(E) Dedicated Equipment Space.
  110.29 In Sight From.
  200.6 Means of Identifying Grounded Conductors.
  Article 210.
  210.4 Multiwire Branch Circuits.
  210.8 Ground-Fault Circuit-Interrupter Protection for Personnel.
  210.8(A) GFCI Protection for Dwelling Units.
  210.8(B) GFCI Protection for Other Than Dwelling Units.
  210.8(D) GFCI Protection for Specific Appliances.
  210.8(F) GFCI Protection for Outdoor Outlets.
  210.11(C)(4) Garage Branch Circuits.
  210.12 AFCI Protection.
  210.18 Branch Circuit Rating.
  210.19 Conductors - Minimum Ampacity and Size.
  210.23 Permissible Loads, Multiple-Outlet Branch Circuits.
  210.24 Branch Circuits - Summary.
  210.52(A)(2) Wall Space for Dwelling Unit Receptacle Outlets.
  210.52(C) Dwelling Unit Receptacle Outlets at Countertops and Work Surfaces.
  210.52(C)(2) & (3) Island and Peninsular Countertops and Work Surfaces.
  210.62 Show Windows.
  210.70 Lighting Outlets Required.
  215.15 Barriers.
  215.18 Surge Protection.
  220.1 Scope.
  225.41 Emergency Disconnects.
  230.7 Other Conductors.
  230.30(B) & 230.43 Wiring Methods for Service Conductors.
  230.67 Surge Protection.
  230.71(B) Two to Six Service Disconnecting Means.
  240.2 Reconditioned Equipment.
  240.4(B) Overcurrent Devices Rated 800 Amperes or Less.
  240.6(D) Remotely Accessible Adjustable-Trip Circuit Breakers.
  240.11 Selective Coordination.
  240.60(E) Fuse Reducers.
  240.89 Replacement Trip Units.
  Article 245 Overcurrent Protection for Systems Rated Over 1000 Volts ac, 1500 Volts dc.
  250.64(G) Enclosures with Ventilation Openings.
  250.68(C) Grounding Electrode Conductor Connections.
  250.102(C)(2) Size of SSBJ for Parallel Conductor Installations.
  250.118 Types of Equipment Grounding Conductors.
  250.130 Equipment Grounding Conductor Connections.
  250.140 Frames of Ranges and Clothes Dryers.
  300.4(E) Cables, Raceways, or Boxes Installed in or Under Metal-Corrugated Roof Decking.
  300.4(G) Fittings.
  Table 300.5 Minimum Cover Requirements.
  300.14 Length of Free Conductors at Outlets, Junctions, and Switch Points.
  Article 305 General Requirements for Wiring Methods and Materials for Systems Rated Over 1000 Volts ac, 1500 Volts dc, Nominal.
  310.15(B)(2) Rooftop.
  312.8(A) Splices, Taps, and Feed-Through Conductors.
  312.10 Screws or Other Fasteners.
  312.102 Doors or Covers.
  314.5 Screws or Other Fasteners.
  314.16(B)(6) Terminal Block Fill.
  314.23(H)(1) Pendant Boxes.
New? First Time? Register for courses for free.

Returning For More? Sign In To Your Account
Other NM Electricians took these electrical continuing education courses with us:
Click on a banner below to go to the page for that course
NEC 2023 Code Changes Update Banner
NEC 2023 Code Changes Update
Course #: 2023-047
Credit Type: Code Change
Credit Hours: 16.0
Price: $149
 
NEC 2020 Code Changes Update Banner
NEC 2020 Code Changes Update
Course #: 2020-12
Credit Type: Code Change
Credit Hours: 16.0
Price: $149
 
NEC 2023 Code Changes Update part 1 Banner
NEC 2023 Code Changes Update part 1
Course #: 2023-105
Credit Type: Code Change
Credit Hours: 8.0
Price: $69
 
NEC 2023 Code Changes Update part 2 Banner
NEC 2023 Code Changes Update part 2
Course #: 2023-106
Credit Type: Code Change
Credit Hours: 8.0
Price: $69