NEC 2020 Code Changes Update - 32 Hours

Approved by the California Department of Industrial Relations for California Electricians License Renewal.

Yes! We Are Approved by the California Department of Industrial Relations for California Electricians' License Renewal.

Electrical Online Course Name Credit Hours Credit Type Course Number Course Availability Course Price
NEC 2020 Code Changes Update - 32 Hours32.0 NEC N/A 2/1/2020
-through-
1/2/2026
$169
-20

$149
This 32 Hour Credit California Electrical Continuing Education License Renewal Course reviews the most important updated 2020 NEC Changes in detail. This course will earn you 32 hours of electrical continuing education of credit type NEC for your electrical license renewal with the CA DIR. In this course we will review all of the most important National Electrical Code Changes; From Global Changes all the way through Chapter 8 is covered. This 1 course is enough to renew your California electrical license for 3 years!
New? First Time? Register for courses for free.

Returning For More? Sign In To Your Account
NEC 2020 Code Changes Update - 32 Hours Course Topics:
  90.2 NEC Scope.
  Article 100 Scope of Article 100 Definitions.
  Article 100 Accessible as Applied to Equipment.
  Article 100 Attachment Fitting.
  Article 100 Bathroom.
  Article 100 Bonding Jumper, Main.
  Article 100 Bonding Jumper, Supply-Side.
  Article 100 Class 1, 2 and 3 Circuits.
  Article 100 Equipotential Plane.
  Article 100 Fault Current & Available Fault Current.
  Article 100 Field Evaluation Body.
  Article 100 Free Air (as applied to conductors).
  Article 100 Habitable Room.
  Article 100 Labeled.
  Article 100 Laundry Area.
  Article 100 Messenger or Messenger Wire.
  Article 100 Photovoltaic (PV) System.
  Article 100 Prime Mover.
  Article 100 Receptacle.
  Article 100 Reconditioned.
  110.12(C) Mechanical Execution of Work. Cables and Conductors.
  110.14(D) Terminal Connection Torque.
  110.21(A)(2) Reconditioned Equipment.
  110.22(A) Identification of Disconnecting Means. General.
  110.24(A) Field Marking.
  110.26(C)(2) Large Equipment.
  110.26(C)(3) Personnel Doors.
  110.32 Workspace About Equipment.
  200.9 Means of Identification of Terminals.
  210.5(C)(1) Branch Circuits Supplied from More Than One Nominal Voltage System.
  210.6(C) 277 Volts to Ground.
  210.8 Ground-Fault Circuit-Interrupter Protection for Personnel.
  210.8(A) GFCI Protection. Dwelling Units.
  210.8(B) GFCI Protection. Other Than Dwelling Units.
  210.8(D) GFCI Protection for Specific Appliances.
  210.8(E) Equipment Requiring Servicing.
  210.8(F) GFCI Protection. Outdoor Outlets.
  210.11(C)(3) Bathroom Branch Circuits.
  210.11(C)(4) Garage Branch Circuits.
  210.12(C) AFCI Protection in Guest Rooms, Guest Suites, and Patient Sleeping Rooms in Nursing Homes and Limited-Care Facilities.
  210.12(D) AFCI Protection. Branch Circuit Extensions or Modifications in Dwelling Units, Dormitory Units, Guest Rooms and Guest Suites.
  210.15 Reconditioned equipment.
  210.19(A)(1) Branch Circuits.
  210.25(B) Common Area Branch Circuits.
  210.52(B)(1) Receptacle Outlets Served.
  210.52(C) Countertops and Work Surfaces.
  210.52(C)(2) Island and Peninsular Countertops and Work Surfaces.
  210.52(C)(3) Receptacle Outlet Location.
  210.52(E)(3) Balconies, Decks, and Porches.
  210.52(G) Basements, Garages, and Accessory Buildings.
  210.63 Equipment Requiring Servicing.
  210.65 Meeting Rooms.
  210.70(A)(1) Lighting Outlets Required. Habitable Rooms.
  210.70(A)(2) Lighting Outlets Required. Additional Locations.
  210.70(B) Lighting Outlets Required. Guest Rooms or Guest Suites.
  210.70(C) Lighting Outlets Required. All Occupancies.
  215.9 Ground-Fault Circuit-Interrupter Protection for Personnel.
  215.10 Ground-Fault Protection of Equipment.
  220.12 Lighting Load for Non-Dwelling Occupancies.
  220.14(J) Dwelling Units.
  220.53 Appliance Load. Dwelling Unit(s).
  225.10 Wiring on Buildings (or Other Structures).
  225.30(B) Common Supply Equipment.
  230.43 Wiring Methods for 1000 Volts, Nominal, or Less.
  230.46 Spliced and Tapped Conductors.
  230.62 Service Equipment Barriers.
  230.66 Marking.
  230.67 Surge Protection.
  230.71 Maximum Number of Disconnects.
  230.75 Disconnection of Grounded Conductor.
  230.82 Equipment Connected to the Supply Side of Service Disconnect.
  230.85 Emergency Disconnects.
  240.6 Restricted Access Adjustable-Trip Circuit Breakers.
  240.21 Feeder Taps.
  240.24(A) Accessibility.
  240.33 Vertical Position.
  240.62 Reconditioned Equipment.
  240.67 Arc Energy Reduction.
  240.86 Series Ratings and Motor Contribution.
  240.87(A) & (B) Arc Energy Reduction. Documentation and Method to Reduce Clearing Time.
  240.87(C) Performance Testing.
  240.88 Reconditioned Equipment.
  240.102 Overcurrent Protection over 1000 Volts, Nominal. Reconditioned Equipment.
  Article 242 Overvoltage Protection.
  250.25 Grounding Systems Permitted to Be Connected on the Supply Side of the Disconnect.
  250.28(A) Main Bonding Jumper and System Bonding Jumper. Material.
  250.30 Grounding Separately Derived Alternating-Current Systems.
  250.53(C) Bonding Jumper.
  250.64(A) Aluminum or Copper-Clad Aluminum Conductors.
  250.64(B) Exposed to Physical Damage.
  250.64(E) Raceways and Enclosures for Grounding Electrode Conductors.
  Table 250.66 Grounding Electrode Conductor for Alternating-Current Systems.
  250.68(C) Grounding Electrode Conductor Connections.
  250.104(A) Metal Water Piping.
  250.109 Metal Enclosures.
  250.122(B) Increased in Size.
  250.148 Continuity of Equipment Grounding Conductors and Attachment in Boxes.
  300.3(B)(1) Paralleled Installations.
  300.15(F) Fitting.
  300.25 Exit Enclosures (Stair Towers).
  310.1 Scope.
  310.10(B) Dry and Damp Locations.
  310.12 Single-Phase Dwelling Services and Feeders.
  310.15(B) Ambient Temperature Correction Factors.
  310.16 Ampacity Table.
  Article 311 Medium Voltage Conductors and Cable.
  312.6 Deflection of Conductors.
  312.8(B) Power Monitoring or Energy Management Equipment.
  314.16(B)(5) Equipment Grounding Conductor Fill.
  314.17(B) Boxes and Conduit Bodies.
  314.27(C) Boxes at Ceiling-Suspended (Paddle) Fan Outlets.
  314.29 Boxes, Conduit Bodies, and Handhole Enclosures to Be Accessible.
  320.30(C) Supporting.
  330.80(C) Thermal Insulation.
  330.130 Hazardous (Classified) Locations.
  334.30 Securing and Supporting.
  334.104 Conductors.
  Article 337 Type P Cable.
  338.2 Definitions.
  338.10(B)(4) Installation Methods for Branch Circuits and Feeders.
  344.10(E) Severe Physical Damage.
  344.14 Dissimilar Metals.
  350.10 Uses Permitted.
  358.10(E) Physical Damage.
  366.23 Ampacity of Conductors.
  392.18(H) Marking.
  392.30(B) Cables and Conductors.
  392.44 Expansion Splice Plates.
  392.46 Bushed Conduit and Tubing.
  404.9 & 10 General-Use Snap Switches, Dimmers, and Control Switches.
  404.14 Rating and Use of Snap Switches.
  404.14(E) Dimmer and Electronic Control Switches.
  404.22 Electronic Control Switches.
  406.4(D)(7) Controlled Receptacles.
  406.5(G) Receptacle Orientation.
  406.9(C) Bathtub and Shower Space.
  406.12 Tamper-Resistant Receptacles.
  406.13 Single-Pole Separable-Connector Type.
  408.4(A) Circuit Directory or Circuit Identification.
  408.6 Short-Circuit Current Rating.
  408.8 Reconditioning of Equipment.
  408.18(C) Connections.
  408.43 Panelboard Orientation.
  410.7 Reconditioned Equipment.
  410.10(D) Bathtub and Shower Areas.
  410.69 Identification of Control Conductor Insulation.
  410.116(C) Installation in Fire-Resistant Construction.
  410.118 Access to Other Boxes.
  410 Part XVI. Special Provisions for Horticultural Lighting Equipment.
  410.176 Locations Not Permitted.
  422.5 Ground-Fault Circuit-Interrupter (GFCI) Protection for Personnel.
  422.16(B)(2) Built-in Dishwashers and Trash Compactors.
  422.16(B)(4) Range Hoods and Microwave Oven/Range Hood Combinations.
  440.9 Grounding and Bonding.
  445.6 Listing.
  445.18 Disconnecting Means and Emergency Shutdown.
  450.9 Ventilation.
  480.7(B) and 480.7(C) Battery System Disconnection.
  480.7(G) Identification of Power Sources.
  490.49 Reconditioned Switchgear.
  511.8 Underground Wiring Below Class I Locations.
  514.11(A) Emergency Electrical Disconnects.
  517.10(B) Not Covered.
  517.18(C) Designated Category 2 (General Care) Pediatric Locations.
  517.30(B)(3) Battery Systems.
  517.30(C) Location of Essential Electrical System Components.
  518.6 Illumination.
  Article 545 Manufactured Buildings and Relocatable Structures.
  555.1 Scope.
  551.2 Definitions.
  555.7 Transformers.
  590.4(G) Splices.
  590.8 Overcurrent Protective Devices.
  600.4(D) Visibility.
  600.6(A)(4) Disconnect. Remote Location.
  600.35 Retrofit Kits.
  620.65 Signage.
  625.1 Scope.
  625.42 Rating.
  625.48 Interactive Systems.
  680.2 Definitions.
  680.4 Inspections After Installation.
  680.21(C) & 680.21(D) GFCI Protection.
  680.22(A)(5) Pool Equipment Room.
  680.26(B)(2) Perimeter Surfaces.
  690.7 Maximum Voltage.
  690.9(B) Device Ratings.
  690.12(B)(2) Rapid Shutdown. Inside the Array Boundary.
  690.31(C) Cables.
  690.31(D) Direct-Current Circuits on or in Buildings.
  700.12(H) DC Microgrid Systems.
  700.12(I)(2) Installation of Unit Equipment.
  700.16 Emergency Illumination.
  705.12 Load-Side Source Connections.
  705.12(B)(1) Feeders.
  705.12(B)(2) Taps.
  705.12(B)(3) Busbars.
  725.24 Mechanical Execution of Work.
  725.144(B) Use of Class 2-LP or Class 3-LP Cables to Transmit Power and Data.
  800 Communications Systems.
New? First Time? Register for courses for free.

Returning For More? Sign In To Your Account
Other CA Electricians took these electrical continuing education courses with us:
Click on a banner below to go to the page for that course
NEC 2020 Code Changes Update - 32 Hours Banner
NEC 2020 Code Changes Update - 32 Hours
Credit Type: NEC
Credit Hours: 32.0
Price: $169
 
NEC 2023 Code Changes Update - 32 Hours Banner
NEC 2023 Code Changes Update - 32 Hours
Credit Type: NEC
Credit Hours: 32.0
Price: $169
 
NEC 2020 Code Changes Update Part 1 - 16Hrs Banner
NEC 2020 Code Changes Update Part 1 - 16Hrs
Credit Type: NEC
Credit Hours: 16.0
Price: $119
 
NEC 2020 Code Changes Update - 24 Hours Banner
NEC 2020 Code Changes Update - 24 Hours
Credit Type: NEC
Credit Hours: 24.0
Price: $139
 
NEC 2020 Code Changes Update Top 50 - 8Hrs Banner
NEC 2020 Code Changes Update Top 50 - 8Hrs
Credit Type: NEC
Credit Hours: 8.0
Price: $89
 
NEC 2023 Code Changes Update Part 1 - 16 Hours Banner
NEC 2023 Code Changes Update Part 1 - 16 Hours
Credit Type: NEC
Credit Hours: 16.0
Price: $119
 
NEC 2023 Code Changes Update - 8 Hours Banner
NEC 2023 Code Changes Update - 8 Hours
Credit Type: NEC
Credit Hours: 8.0
Price: $89
 
NEC 2020 Code Changes Update Part 2 - 16Hrs Banner
NEC 2020 Code Changes Update Part 2 - 16Hrs
Credit Type: NEC
Credit Hours: 16.0
Price: $119
 
2020 NEC Grounding and Bonding Part 1 Banner
2020 NEC Grounding and Bonding Part 1
Credit Type: NEC
Credit Hours: 2.0
Price: $35
 
NEC 2023 Code Changes Update Part 2 - 16 Hours Banner
NEC 2023 Code Changes Update Part 2 - 16 Hours
Credit Type: NEC
Credit Hours: 16.0
Price: $119
 
Electrical Safety in the Workplace Banner
Electrical Safety in the Workplace
Credit Type: NFPA-70E
Credit Hours: 6.0
Price: $79
 
2020 NEC Grounding and Bonding Part 2 Banner
2020 NEC Grounding and Bonding Part 2
Credit Type: NEC
Credit Hours: 2.0
Price: $35
 
Available Fault Current Banner
Available Fault Current
Credit Type: NEC
Credit Hours: 6.0
Price: $79