500.4 Documentation.

Areas designated as hazardous (classified) locations as well as those areas determined to be unclassified must be documented on an area classification drawing and other associated documentation.
Click to Enlarge
Areas designated as hazardous (classified) locations as well as those areas determined to be unclassified must be documented on an area classification drawing and other associated documentation.

Code Change Summary: Revisions made to address required documentation for hazardous locations.

In the 2023 NEC®, changes made in Section 500.4 now make it clear that areas designated as hazardous (classified) locations as well as those areas determined to be unclassified must be documented on an area classification drawing and other associated documentation. This documentation must be made available to the authority having jurisdiction (AHJ) and those authorized to design, install, inspect, maintain, or operate electrical equipment at the specified location.

One problem that often arises for the electrician and the inspector is determining which areas of a construction project are considered hazardous locations and require specific wiring methods or equipment in accordance with NEC® Chapter 5. This is usually caught during the plans review process before any permits are issued but sometimes the inspector sees something in the field during construction that was missed by or not disclosed to the city plans examiner.

Electricians and inspectors often take it upon themselves to determine if an area is considered hazardous, to what extent, and the appropriate wiring methods or equipment needed based on what type of hazardous location they feel that it might be. This is out of the scope of the NEC® and should be handled by the appropriate qualified design personnel in conjunction with the AHJ, and using other applicable safety standards (see informational note 1 in NEC® Section 500.4).

Determining the classification of hazardous locations requires knowledge of the type of flammable or combustible materials present, the quantity of the materials, and knowing the likelihood that the processes occurring around the materials could create a situation where the combustible or flammable materials become present in a large enough quantity to create a hazard.

Sometimes a location designated as hazardous might have adjacent spaces that are cut off from the area, or ventilated in such a manner that would render them unclassified in accordance with the NEC®. A good set of plans should note all areas of a construction project that have been designated as a hazardous location, the classification of the hazardous location, and now, all areas that have been determined NOT to be classified as a hazardous location.

Below is a preview of the NEC®. See the actual NEC® text at NFPA.ORG for the complete code section. Once there, click on their link to free access to the 2023 NEC® edition of NFPA 70.

2020 Code Language:

500.4 Documentation. All areas designated as hazardous (classified) locations shall be properly documented. This documentation shall be available to those authorized to design, install, inspect, maintain, or operate electrical equipment at the location.

2023 Code Language:

500.4 Documentation. Areas designated as hazardous (classified) locations or determined to be unclassified shall be documented on an area classification drawing and other associated documentation. This documentation shall be available to the authority having jurisdiction (AHJ) and those authorized to design, install, inspect, maintain, or operate electrical equipment at the location.

Did You Like This? Let Us Know With A Like! Thanks!

500.4 Documentation.

Below is a Real Question from our Electrical Continuing Education Courses for Electrical License Renewal:

Based on the 2023 NEC, which of the following is true?

A: Only those areas designated as hazardous must be documented on an area classification drawing.
B: Only unclassified areas must be documented on an area classification drawing.
C: Area classification drawings must be in color.
D: Areas designated as hazardous (classified) locations as well as those areas determined to be unclassified must be documented on an area classification drawing.
Please register or sign in for electrical continuing education courses.

If you were already signed in, your session probably expired, please sign back in.